Calibration is necessary every time you change tips and/or materials. (Note: This information is also in your User Guide)

Process

Step 1: Install a clean plastic sheet and allow vacuum pressure to reach -15 Hg or  
            greater.

Step 2: Go into the Calibrate menu and run Auto Z Stage Zero Calibration. If this
             calibration fails, follow Steps 2a through 2i to set the Z Zero with Shim.

                 2a From the main menu on the keypad select Operator Control and
                      press enter.

                 2b Select Calibrate and press enter.
                 2c Select Set Z Stage Zero and press enter.
                 2d Select Set Z Zero with Shim and press enter. The Z stage moves into
                       position and the head moves out.